During installation 1000 ft 12/2 Romex cables can easily be pulled through holes because of their smooth sheathing. 250 ft roll of 12-2 Romex wires are lighter than wires with metallic sheaths, so they are easier to handle, unspool, and straighten. What Are The Benefits of 12-2 Romex Wires?ġ000 ft 12-2 Romex are well-insulated so they may be installed in plastic pipes or boxes without any need to ground the box. 12-gauge Romexs are acceptable on 20 amps and 15 amps circuits. This will prevent a situation where both wire gauges will be connected. ¢ Models: ARYG12LHTBP, ARYG14LHTBP, ARYG18LHTBP, ARYG24LHTBP, ARYG30LHTBP, ARYG36LHTBP, ARYG45L- HTBP, and ARYG54LHTBP. If a home or office will need both 15 and 20 amps circuits, it is better to use 12-2 gauge wire exclusively. NOTE: Do not place any wiring or illumination in the maintenance space, as they will impede ser- vice. Consequently, they should only be used 15 amps circuits. The 14-2 AWG cables are thinner than the 12-2 cables. Should You Choose a 14-2 or 12-2 Romex Wire? Reliable 12-2 AWG cables can also work with THWN or THHN-rated wires because they can handle a temperature of up to 194 degrees Fahrenheit. 12-2 Romex can work with a 15 amps or a 30 amps power circuit. They can handle the current and heat of circuits that are lower and higher than 20 amps. However, 100 ft 12-2 Romex are versatile. In most cases, a 20 amps circuit breaker should be installed with these cables.
:max_bytes(150000):strip_icc()/electrical-wiring-1152909_07_maxwiresconduit_3217-b52f0ad0e4f24203b3b1b1cbb8825ba5.jpg)
How Many Amps is a 12-2 Romex Wire Good for?Ī 12 gauge Romex wire is rated for a 20 amps circuit. 50 ft Romex 12-2 cables are used mainly for indoor wiring in homes and office buildings. The individual conductors usually have white, black, and red insulation. Most 1000 ft 12-2 Romex cables have a yellow outer jacket to differentiate them from 14-gauge and 10-gauge wires. It protects them from exposure, rust, or bridging (accidental contact between the live and neutral wires). This type of wire is thinner than 12 gauge and is not. The tough non-metallic sheathing serves as a casing for the individual wires. When you are wiring a circuit that runs through more than one room, you have to use 14 gauge wire. A 12-2 Romex wire also has a bare or insulated ground wire bundled with the current-carrying wires. The second number (2) indicates the number of current-carrying wires. The first number (12) refers to the gauge under the American Wire Guage (AWG) system. Is there a better alternative that doesn't involve a new 12-3 run back to the breaker box.12-2 Romex wires are copper wires insulated and bundled together in a single non-metallic sheath.Are none, one, or both of these configurations safe?.Its applications are outlined in NEC 2008 and NEC 2011 Article 334. Again, I'd twist the neutral (white) together in a wire nut, and I'd crimp the 12-2 ground with the 12-3 ground. Applications: Non-metallic sheathed NM-B cable is used in normally dry installations in residential wiring, as branch circuits for outlets, lighting and other residential loads. At the fan switch, I would connect the 12-3 (black) hot. At the light switch, I would connect the 12-3 (red) hot. One of these pieces would then feed into the top of the light switch while the other one of these pieces would feed into the fan switch. My plan would be to twist the 12-2 hot (black) feed from the breaker box in a wire nut with two pieces of 12 gauge (black). Finally, I'd crimp the 12-2 ground with the 12-3 ground. I'd then directly connect the 12-2 neutral (white) with the 12-3 neutral (white) in a wire nut. My plan was to connect the 12-2 hot (black) to the top of the switch, then connect both 12-3 hots (red & black) to the bottom of the switch. One switch would operate both the light and the fan.

Here are the two configurations I thought were possible. In my switch outlet box, I have a 12-2 cable on a 15A breaker. While I'd like to be able to operate the light on the fan, and the fan itself separately, it's not an end requirement. For example, there is aluminum wiring in some homes, and aluminum wires have their own ampacity-carrying capacity. I will ground the ceiling fan box with the run back to the breaker box. These ratings are for standard copper NM sheathed cable, but there are instances where these amperage ratings vary. I've got a ceiling fan mount in place with a supporting brace that can support the weight of the fan. I'm installing a ceiling fan into a room that has no existing ceiling mount (no light or ceiling fan previously existed).